Can I move my HyperRAID array?
HyperRAID arrays can be moved to other machines which support HyperRAID (any Wavestore V6.14 or later) and will continue to work. Just remember to set up the array in the new machine in the same geometry (eg, A7+2) as the old machine. The disks can be put into the new machine in any order, but it might be less confusing if they are kept in the same order (so the logical disk order D1 D2 ... corresponds to the slot order s01 s02 ...).
When moving, ensure the entire array is moved at once. The best way is to power off the machines when the disks are moved.
- Power off the source machine
- Remove the disks from the source machine
- Ensure there is no disk array on the target machine, or if there is one then it's the correct geometry.
- Power off the target machine
- Add the disks to the target machine
- Power on the target machine
- Create the disk array on the target machine with the correct geometry, if it was not created before.
If more disks are to be added without losing the data, add another group (eg, change A7+2 to A7+2,5+2). The disks added to form a new group should be newly formatted to ensure there's no conflict. After major changes like this, either format the whole array (losing your data) or click AddSwappedDrives to ensure the already-formatted parts are recognised as such.